home

prodotti download novitą assistenza tecnica contatti

chi siamo

     

elenco completo laboratori

lab. didattici elettronica

lab. didattici comunicazioni e networking

lab. didattici automazione

 

PER SAPERNE DI PIU'

scarica brochure

richiedi maggiori info

richiedi un preventivo

contatta PATRUCCO

 

PRODOTTI COLLEGATI

Circuit Logix Pro
software disegno e simulazione elettronica

Electronics CBT
corso multimediale di elettronica

Strumentazione elettronica
alimentatori, generatori di funzioni, multimetri, oscilloscopi

HDGuard
protezione hard disk

INiS
gestione aule informatiche

 

ELETTRONICA

Laboratori didattici per l'elettronica
Apparecchiature per esercitazioni e test

KL-600: Laboratorio controlli basato su micro-computer

The KL-600 Microcomputer Sensing and Control System is a comprehensive sensor/transducer control training system that incorporates industrial-grade components with various control circuits and load units. Its modular and closed-loop control circuits allow implementation of open-ended, individual control loops used in industrial applications.

The KL-600 uses only industrial-standard sensors/transducers (0~10V, 4~20mA) and is equipped with RS-232 and PIO interfaces for computer interface control experiments. Control programs can be written and down-loaded to the Single-Chip microprocessor on KL-61001 main unit from computers through RS-232 interface.

 

FEATURES

a Comprehensive sensor/transducer and control training system.

a Incorporates industrial grade components.

a Uses industry standard 0~10V, 4~20mA devices.

a Features RS-232 for connection to personal computer.

a Built-in 8031 microcontroller and monitor EPROM.

a 17 experiment modules form basis for a wide range of fully documented experiments.

a Main units and experiment modules also available separately for economical construction of class sets.

 

LIST OF EXPERIMENTS

a Characteristics of Various Sensors

a General Sensor Characteristics Experiments

a AD590 Temperature Transducer Experiments

a Thermocouple Temperature Transducer Experiments

a PT-100 Temperature Transducer Experiments

a Humidity Transducer Experiments

a Load-Cell Weight Measurement Experiments

a LVDT Transducer Experiments

a Photovoltaic Transducer Experiments

a Linear Scale Experiments

a Infrared Transducer Experiments

a Ultrasonic Transducer Experiments

a Pressure Sensor Experiments

a V/F, F/V Converter Experiments

a Accessories (KL-68011)

 


THE KL-600 MAIN UNIT

The main unit incorporates all necessary equipment for use with the eleven experiment kits. A socketed industry-standard 8031 microcontroller is fitted to the system, along with a monitor EPROM, and may be programmed from an IBM compatible personal computer by way of an RS-232 link.

The main unit also contains a 12-bit analogue to digital converter and 12-bit digital to analogue converter, as well as amplifiers and a multi-rail power supply.


KL-600 EXPERIMENTS MODULES

The KL-600 system contains the seventeen experiment modules and all load units necessary to conduct a wide range of experiments. These combine to make the following eleven distinct experiment kits:

 
 
 

Sensor and General Transducer Characteristics

 
 
 

Temperature Transducer Experiments

 
 
 

Humidity Transducer Experiments

 
 
 

Load Cell Transducer Experiments

 
 
 

LVDT Transducer Experiments

 
 
 

Photovoltaic Transducer Experiments

 
 
 

Linear Scale Experiments

 
 
 

Infrared Transducer Experiments

 
 
 

Ultrasonic Transducer Experiments

 
 
 

Pressure Sensor Experiments

 
 
 

V/F, F/V Converter Experiments


LIST OF EXPERIMENTS

The full list of experiments performed using the above experiment kits and detailed in the experiment manual are:

  1. Characteristics of Various Sensors:
    A. Photodiode
    B. Photo-interruptor
    C. Magnetic sensor
    D. Pyroelectric detector
    E. Thermistor
    F. Reed switch
    G. Inclination sensor
    H. Limit switch
    I. Mercury switch
    J. Vibration switch
    K. Condenser Microphone
    L. Dynamic Microphone

     

  2. General Sensor Characteristics Experiments
    A. Gas/smoke detector
    B. Ethanol sensor
    C. Hall-effect (analogue)
    D. Hall-effect (digital)

     

  3. AD590 Temperature Transducer Experiments
    A. AD590 characteristics and converter circuit
    B. Boiler temperature control
    C. Digital thermometer
    D. Computer I/O interface control
    E. Single-chip microprocessor control

     

  4. Thermocouple Temperature Transducer Experiments
    A. Thermocouple characteristics curve and converter circuit
    B. Fire alarm
    C. Digital thermometer
    D. Computer I/O interface control
    E. Single-chip microprocessor control

     

  5. PT-100 Temperature Transducer Experiments A. PT-100 resistor-temperature characteristics measurement
    B. Fire alarm
    C. Digital thermometer
    D. Computer I/O interface control
    E. Single-chip microprocessor control

     

  6. Humidity Transducer Experiments
    A. Humidity transducer characteristics and converter circuit
    B. Greenhouse humidity control
    C. Digital thermometer
    D. Computer I/O interface control
    E. Single-chip microprocessor control

     

  7. Load-Cell Weight Measurement Experiments
    A. Load cell characteristics and converter circuit
    B. Weight measurement
    C. Digital scales
    D. Computer I/O interface control
    E. Single-chip microprocessor control

     

  8. LVDT Transducer Experiments
    A. LVDT characteristics and converter circuit
    B. Position measurement
    C. Distance measurement
    D. Computer I/O interface control
    E. Single-chip microprocessor control

     

  9. Photovoltaic Transducer Experiments
    A. Photovoltaic transducer characteristics and converter circuit
    B. Characteristics of various light sources
    C. Automatic lighting
    D. Digital luxmeter
    E. Computer I/O interface control
    F. Single-chip microprocessor control

     

  10. Linear Scale Experiments
    A. Characteristics of linear scale
    B. Measurement of movements
    C. Computer I/O interface control

     

  11. Infrared Transducer Experiments
    A. AC/DC characteristics
    B. Counter
    C. Infrared remote control

     

  12. Ultrasonic Transducer Experiments
    A. Ultrasound characteristics measurement
    B. Motion detector

     

  13. Pressure Sensor Experiments
    A. Zero-pressure input characteristics
    B. Full-scale pressure measurement
    C. Over-pressure alarm

     

  14. V/F, F/V Converter Experiments
    A. VFC/FVC characteristics
    B. Computer I/O interface control
    C. Programmable time pulse generation

SPECIFICATIONS

KL-600 Main Unit

Fixed DC Power Supply

Voltage range: +5V, -5V, +12V and -12V
Maximum current output: 3A for +5V rail, 1.5A for +12V rail, 300mA for others
Output overload protection

Interface Ports

RS-232C interface, 25-pin D-type connector
PIO interface, 25-pin D-type connector
Bus and PIO interface, 60-pin connector

Single-Chip Processor

8031 microcontroller fitted in ZIF socket
8 control lines
DRAM used for adjustable sensor reference value

EPROM

2764 or equivalent fitted in ZIF socket

Status Display

(1) Input voltage measurement
Range: 2000mV, 20V
Accuracy: ±0.05% of reading + 4 counts
Input impedance: 10MW

Display: 4½ digits
(2)Sensor input measurement
Sensor types: TEMP, %RH, LUX, WEIGHT, AUX
Accuracy: ±0.05% of reading + 4 counts
Display: 4½ digits

Preset Level

4-digit thumbwheel switch
Maximum value: 4095

D/A Converter

One 12-bit DAC
Resolution: 1.22mV/bit
Analogue output and control:
OUT + : +DC OFFSET 0V ~ +4.096V unipolar
OUT - : -DC OFFSET 0V ~ -4.096V unipolar
OUT BP: DC OFFSET -2.048V ~ +2.048V bipolar

A/D Converter

One 12-bit ADC
Resolution: 1.22mV/bit
Input voltage range: 0V ~ +5V
Time pulse frequency: 3.579545MHz
Control signals: state, pole, over Voltage indication

Amplifiers

Instrumentation amplifier: ±Vi input, Vo output, adjustable gain
Differential amplifier: ±Vi input, Vo output
Comparator: ±Vi input, Vo output
Alarm amplifier: buzzer with driver circuit

Selectors

PIO/single-chip selector
Manual/single-chip selector

Potentiometer

100KW, B-type

Accessories

Power lead, connecting leads, PC link cable, fuse, dust cover, software disk, and user manual
 

Power Supply

110/220V AC ±10% 50/60Hz

 

Le immagini e le descrizioni sono indicativi. Le caratteristiche tecniche possono subire variazioni in fase di costruzione della ditta fornitrice.

 

Copyright © PATRUCCO snc. Tutti i diritti riservati. Riproduzione o copia proibita.