ELETTRONICA
Laboratori didattici
per l'elettronica
Apparecchiature
per esercitazioni e test |
|
KL-100: Laboratorio elettrico (circuiti lineari 1)
|
The
KL-100 Electricity Lab is a
comprehensive and self-contained system suitable for tuition and
experimentation with electricity circuits. All necessary
equipments for electricity circuit experiments such as power
supply, function generator, analog and digital meter are
installed on the main unit. The 11 modules covers a wide variety
of essential topics in the field of electricity circuit. It is
indeed a time and cost saving system for both students and
researcher interested in training, developing and testing
circuit prototypes. |
|
FEATURES
a
Ideal for electricity circuit
experiments and design exercises.
a
Integrated trainer, with complete
curriculum.
a
Complete with power supplies and test
systems for easy and efficient experimentation.
a
Universal breadboard (1680 tie points)
for circuit design and prototyping.
a
All modules equipped with an 8-bit DIP
switch for fault simulation.
TYPE OF EXPERIMENTS
a
Experiments for Basic Electricity
a
Experiments for Magnetism
a
Experiments for Basic Electronic Circuits
a
Experiments for Simple Electronic Circuits
a
Experiments for Industrial Control
Applications
a
Experiments for Oscillator Characteristics
and Applications |


Storage cabinet for easy
storing all modules. |
|
|
|
|
|
THE KL-100 MAIN
UNIT

The main unit
incorporates all necessary equipment for use with the eleven
plug-on training modules. Power supply, function generator,
and analogue and digital meters are all built-in.
The DC power supply
provides fixed ±5V and ±12V at 0.3A, a variable ±3V ~ ±18V
at 1A, and a transformer provides a 9V~0V~9V AC output at up
to 500mA.
The function generator
offers sine, square, and triangle waveforms at frequencies
from 10Hz ~ 100kHz in 4 ranges.
The main unit is also
supplied with a removable 1680 tie point universal
breadboard for general experimentation and prototyping.
KL-100
EXPERIMENTS MODULES
11 modules
form the basis for the 59 experiments detailed in the
comprehensive experiment manual. Each module contains the
experiment circuit which is clearly illustrated by a cicuit
diagram on its top panel. Switch faults are also
incorporated into the modules for simulating fault
situations.
|
1.
KL-13001 Basic Electricity Experiment Module
2.
KL-13002 Magnetism Introduction Experiment Module
3.
KL-13003 Magnetic Field Experiment Module
4.
KL-13004 Ampere's Rule Experiment Module
5.
KL-13005 Fleming's Rule Experiment Module
6.
KL-13006 Induction Experiment Module
7.
KL-13007 Fundamental Electronic Circuits Experiment Module
8.
KL-13008 Basic Electronic Circuits (1) Experiment Module
9.
KL-13009 Basic Electronic Circuits (2) Experiment Module
10.
KL-13010 Special Electronic Components Experiment Module
11.
KL-13011 Oscillator Characteristics & Applications
Experiment Module
LIST OF EXPERIMENTS
The full list of
experiments performed using the above modules and detailed
in the experiment manual are:
-
Basic Electricity Experiments
-
DC voltage measurement
-
Using an ohmmeter
-
Resister characteristics
-
DC current measurement
-
Ohm's law
-
Power in DC ciruits
-
Series-parallel circuits and
Kirchhoff's law
-
Superposition, Thevenin's and
Norton's theorems
-
Maximum power transfer theorem
-
DC RC circuits and transient
phenomena
-
AC voltage measurement
-
AC current measurement
-
AC RC circuits
-
AC RL circuits
-
AC RLC circuits
-
Power in AC circuits
-
Transformer characteristics
-
Series resonant circuits
-
Parallel resonant circuits
-
LC filters
-
Magnetism Experiments
-
Magnetic devices
-
Magnetic fields
-
Drawing magnetic curves
-
Magnetic field strength
-
Lenz's and Faraday's laws
-
Ampere's rule
-
Fleming's rule
-
Self induction
-
Mutual induction
-
Magnetic flux detection
-
Fundamental Electronic
Circuits Experiments
-
Diode characteristics
-
Rectifier circuits
-
Filter circuits
-
Zener diode characteristics
-
LED characteristics
-
Transister characteristics
-
Multimeter functions
-
FET characteristics
-
SCR characteristics
-
UJT characteristics
-
Basic Electronic Circuits
Experiments
-
Simple amplifier
-
Complimentary amplifier
-
Voltage regulator
-
Push-pull amplifier
-
Wheatstone bridge
-
Dimmer circuit
-
Multistage cascading amplifier
-
Relay characteristics
-
Touch controlled switch
-
Control Applications
Experiments
-
CDS characteristics
-
Light controlled circuit
-
Thermister characteristics
-
Temperature controlled circuit
-
Sound controlled circuit
-
Oscillator Characteristics &
Applications Experiments
-
Blocking oscillator
-
Electronic birdcall circuit
-
Astable multivibrator
-
LED flasher circuit
-
LC resonant circuit
SPECIFICATIONS
|
KL-100 Main Unit
|
|
Fixed DC Power Supply
|
Voltage range: +5V, -5V,
+12V and -12V
Maximum current output: 300mA
Output overload protection |
|
Variable DC Power Supply
|
Voltage range: +3V ~
+18V, -3V ~ -18V
Maximum current output: 1A
Output overload protection |
|
AC Power Supply |
Voltage range: 9V~0V~9V
Maximum current output: 500mA
Output overload protection |
|
Function
Generator |
Four frequency ranges:
10Hz to 100Hz
100Hz to 1KHz
1KHz to 10KHz
10KHz to 100KHz
Waveforms: Sine, Square, Triangle
Accuracy: ±5% of full scale value
Output impedance: 50W
Output voltage: ³18Vp-p (open-loop); ³9Vp-p (with 50W
load) |
|
3½ Digit
Digital Meter |
DC Voltage range: 2V,
200V
DC Voltage accuracy: ±0.3% of reading + 1 digit
DC current range: 200µA, 2000mA
DC current accuracy: ±0.5% of reading + 1 digit
|
|
Analogue
Meters |
AC current: 0 ~ 100mA ~
1A
AC Voltage: 0 ~ 15V
DC current: 0 ~ 100mA ~ 1A
DC Voltage: 0 ~ 20V |
|
Speaker
|
8W,
0.25W speaker with driver circuit |
|
Variable
Resistors |
1kW,
0.25W variable resistor with 3 terminals (A, B, C)
10kW, 0.25W variable resistor
with 3 terminals (A, B, C)
100kW, 0.25W variable
resistor with 3 terminals (A, B, C)
1MW, 0.25W variable resistor
with 3 terminals (A, B, C) |
|
Removable
Solderless Breadboard |
1680 interconnected tie
points, accepting all DIP devices, components with leads
and solid wires of AWG #22-30 (0.3mm to 0.8mm)
|
|
Accessories
|
Power lead, connecting
leads, fuse, dust cover, and user manual
|
|
Power
Supply |
110/220V AC ±10% 50/60Hz
|
|
Physical
Characteristics |
Dimensions: 400mm (width),
300mm (depth), 130mm (height)
Weight: 5.8kg |
|
|
|
|
Le immagini e
le descrizioni sono indicativi. Le caratteristiche tecniche possono
subire variazioni in fase di costruzione della ditta fornitrice. |
|
|
|
|